Partner Manufacturers - Product Information

STV-4540D - Server Technology - PRO1 Switched PDU Switched & Managed Vertical Ports 24 x C13 with Feed C20 16A (ServerTech)


STV-4540D - Technical drawing

Description:
Server Technology PRO1 Switched PDU STV-4540D Switched & Managed Vertical 24 x C13 with Feed C20 16A

Switched PRO1 with PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 16A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx **

The Server Technology® PRO1 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to
determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billinggrade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These
power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI
interfaces as well as through SNMP. The PRO1 Switched “Primary”PDU can be connected to as many as three (with optional module) PRO1 Switched
“Link”PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Features:
Network Monitoring
Gain access to valuable data through connections including
HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S),
RS-232 serial, and more.

Hot - Swap Network Card
Network access is ensured when power is lost to the primary
unit with backup power provided by the primary link unit.

Star Multi - Linking
Provides the ability to link up to four power circuits using one
IP address. Primary link provides backup power to network
card.

Temperature/Humidity Monitoring
Primary and Link units each support two external 10' (3m) T/H
probes. Receive SNMP-based alerts and email notifications.

Auto - Flip Current Display
Easy-to-read LEDs display current per phase to help prevent
overloads and simplify three-phase load balancing in highdensity cabinets.

Per - Inlet Power Sensing
Meets ANSI C12.1 for billing-grade accuracy of Current per
phase. PIPS includes voltage, active power, apparent power,
power factor, and energy.

Branch Circuit Protection
This PDU meets the UL and IEC 60950-1 requirement for
branch circuit protection through use of UL489 rated
magnetic-hydraulic circuit breakers or UL248 fuses.

Outlet Control
On Switched rack PDUs, cycle power to individual outlets or
groups of outlets to reboot servers. Or, power off unused
receptacles.

High Retention Locking Outlets
Receptacles have high retention and are compatible with PLock type power cords.

High Temperature Rating
This product has been tested and approved for safe and
reliable operation in 60 °C data center environments.


Power Pivot™
The 90 degree rotatable power cord allows for standardized
deployment at any facility no matter where power must be
routed.

Flexible Mounting
Includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for
details).

Colour Identification
Choose from six colors to designate circuits for rack PDUs in
the data center. Color options include Blue, Red, Green, White,
Yellow, and Black.

STV-4540D - Technical Diagram

Specification:
Switched PRO1 with PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 16A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx **

Inputs
Input Voltage (V): 230
Frequency 50/60 Hz
Input Plug: IEC C20 230V Inlet
Input Current (A): 16
Input Current Rated (A): 16
Input Power Capacity (kW): 3.6

Outputs
Connect or Rating
(24) x IEC 60320/C13 Global Rating: ≤ 10A @230V L-N


Branch Circuit Protection
UL 489, CSA C22.2 No. 5 & IEC/EN60947-2 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: ≤ 16A, 5 kAIC Interrupt Rating

Physical
Dimensions: 69.0in tall x 1.75in wide x 2.25in deep [1753mmx 45mmx 58mm]

Environmental
Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RHto 90%RHnon-condensing | 6,500ft/2kmelevation
St orage Environment: -40°F to 185°F / -40°C to 85°C | 8%RHto 90%RHnon-condensing | 50,000ft/15kmelevation
Quiescent/ Unloaded Power Draw: < 10W for all configurations

Communications & Security
10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6,
LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications
Global:
TUV T-Mark to EN60950-1:2006+A11+A1+A12+A2
EMC to EN55024 (2010) and EN55032 (2012)
CE Compliant
RoHS, EuropeanHazardous Materials Directive (Recast) 2011/65/EU
WEEE Compliant

Measurement Accuracy
Input Meas urement Accuracy:
LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUICurrent = ± 1% at 0.01 amp resolution (above 0.25 amp)
Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
Active Power = ± 1% at 1 watt resolution
Apparent Power = ± 1% at 1 volt-amp resolution
Power Factor = ± 3% at 0.01 resolution
Crest Factor = ± 10% at 0.1 resolution
Energy = ± 1% at 0.1 kilowatt-hour resolution

Optional Accessories
EMTH-2-10 Combination Temperature/Humidity Probe, 10ft (3m)
EMCU-1-1C Environmental Monitor adding:
- Two (2) EMTH-2-10 temperature/humidity ports (one probe included)
- One (1) EMWS-1-1 water sensor port (probe sold separately)
- Four (4) dry contact (NO/NC) monitoring points
- One (1) 8-bit analog-to-digital converter (0 to 5VDC)
KIT-SUS-01 StartUp Stick™ for rapid configurationMounting Brackets
- Buttons (KIT-0020) included for tool-less mounting (see diagram)
- See the Mounting Bracket Guide for further suggestions
- Custommounting options available. Contact your local Server Technology representative
Cable RetentionDevices for non-locking cords
- EZip
- Cable Sleeve

Click here for further information